MLN SIL 25/1
4 mm system / Measuring leads
Product | MLN SIL 25/1 | ||||||||||||||||||
description | Measuring lead, at either end 4 mm diameter plug with caged spring and 4 mm diameter socket for tower construction. Nickel-plated copper beryllium contact spring. Highly flexible, double insulated stranded lead, grip and lead shatter-proof. Built in colour indicator for easy identification of insulation damages. | ||||||||||||||||||
operating instruction | BA401 | ||||||||||||||||||
article-no. / *colour |
9340901xx
|
||||||||||||||||||
drawing | |||||||||||||||||||
technical data | |||||||||||||||||||
rated voltage | 30 VAC / 60 VDC | ||||||||||||||||||
measurement cat. acc. to IEC 61010 | O (2) | ||||||||||||||||||
rated current (consider derating curve) |
16 A | ||||||||||||||||||
material plug | brass, nickel plated | ||||||||||||||||||
housing material | PA | ||||||||||||||||||
temperature range acc. To IEC61010(1) | -15 °C to +70 °C | ||||||||||||||||||
inflammability class acc. to UL 94 (only valid for basic material of housing) |
V-2 | ||||||||||||||||||
cable length | 25 cm | ||||||||||||||||||
conductor size | 1 mm² | ||||||||||||||||||
cable material | SIL |
(1) contact the manufacturer for applications at deviating temperature ranges
(2) without rated measurement category, for other circuits that are not directly connected to mains
stand: 21.06.2022